Thiết bị đo lưu lượng FT1 Fox Thermal
Nhà phân phối Flowmeter Fox Thermal Instruments chính hãng tại Việt Nam
FT1 Fox Thermal | Đồng hồ đo lưu lượng khí Fox Thermal
Fox Thermal Model FT1 Thermal Gas Mass Flow Meter
The Model FT1 is a multiple award winner due to its innovative design elements such as the DDC-Sensor™ technology platform that allows it to operate using the Gas-SelectX® gas menu selection tool.
Key Features:
- Insertion & Inline Styles
- DDC-Sensor™ Technology
- Gas-SelectX® Gas Selection Menu
- Zero CAL-CHECK® Calibration Validation
- Scroll down for more features/benefits!
Industrial Applications:
- Wastewater Aeration
- Natural Gas Monitoring
- Pure Gas Monitoring
- Biogas Monitoring
Technical Specifications
Fox Thermal Model FT1 Thermal Mass Flow Meter & Temperature Transmitter
Performance Specs
Type
Insertion
Inline
Flow Accuracy:
Air: ± 1% of reading ± 0.2% of full scale.
Other Gases: ± 1.5% of reading ± 0.5% of full scale.
Accuracy specification applies to customer's selected flow range
Straight, unobstructed pipe requirement:
15 diameters upstream; 10 downstream.
8 diameters upstream; 4 downstream.
Flow Repeatability:
± 0.2% of full scale
Flow Response Time:
0.8 seconds (one time constant)
Temperature Accuracy:
± 1° F (± 0.6° C)
Calibration:
Factory Calibration to NIST-traceable standards
Zero CAL-CHECK®: In situ, operator-initiated calibration validation
Operating Specs
Type
Insertion
Inline
Flow Units (field selectable):
SCFM, SCFH, NMPS, NM3/M, NM3/H, NM3/D, NLPS, NLPM, NLPH, MCFD, MSCFD, SCFD, MMSCFD, MMSCFM, SM3/M, SM3/D, SM3/H, LB/S, LB/M, LB/H, LB/D, Kg/S, Kg/M, Kg/Hr, SLPM, SFPM, MT/H
Flow Rates:
15 to 25,000 SFPM (0.07 to 120 NMPS)
Turndown:
up to 1000:1; 100:1 typical
Flow Ranges:
Pipe Size | SCFM | NM³/HR |
---|---|---|
1.5" (40mm) | 0 - 354 | 0 - 558 |
2" (50mm) | 0 - 583 | 0 - 920 |
2.5" (63mm) | 0 - 830 | 0 - 1,200 |
3" (80mm) | 0 - 1,280 | 0 - 2,020 |
4" (100mm) | 0 - 2,210 | 0 - 3,480 |
6" (150mm) | 0 - 5,010 | 0 - 7,910 |
8" (200mm) | 0 - 8,680 | 0 - 13,700 |
10" (250mm) | 0 - 13,600 | 0 - 21,450 |
12" (300mm) | 0 - 19,400 | 0 - 30,600 |
Pipe Size | SCFM | NM³/HR |
---|---|---|
0.75" (20 mm) | 0 - 93 | 0 - 146 |
1" (25 mm) | 0 - 150 | 0 - 237 |
1.25" (32 mm) | 0 - 260 | 0 - 410 |
1.5" (40 mm) | 0 - 354 | 0 - 558 |
2" (50 mm) | 0 - 538 | 0 - 920 |
2.5" (63 mm) | 0 - 830 | 0 - 1,200 |
3" (80 mm) | 0 - 1,280 | 0 - 2,020 |
4" (100 mm) | 0 - 2,210 | 0 - 3,480 |
6" (150 mm) | 0 - 2,500 | 0 - 3,950 |
Note: To determine if the FT4A will operate accurately in other pipe sizes, divide maximum flow rate by the pipe area. The application is acceptable if the resulting velocity is within the velocity range above.
Note: Consult factory for flow ranges above those listed. Inline meters above 5,000 SCFM (7,900 NM3/H) air may require third party calibration.
Gas Pressure (max):
740 psig (51 barg)
316 SS inline w/NPT ends: 300 psig (20 barg)
316 SS inline w/150lb flanges: 230 psig (16 barg)
CS inline w/NPT ends: 300 psig (20 barg)
CS inline w/150lb flanges: 285 psig (20 barg)
Check with factory for higher pressure options.
NOTE: When teflon ferrule option ordered, gas pressure is 60psig (4.1 barg) maximum.
Relative Humidity:
90% RH maximum; non-condensing
Temperature:
DDC-Sensor™: -40 to 250°F (-40 to 121°C)
Enclosure: -40 to 158°F (-40 to 70°C)
*Note: Display dims below -4°F (-20°C); function returns once temperature rises again.
Input Power:
Input power: 12 to 28VDC, 6 watts max. (CE requirement)
Full input power input range: 10 to 30VDC, 6 watts maximum.
Inputs/Outputs
- All outputs and communication circuits are galvanically isolated.
- Standard 4-20mA output proportional to the flow rate; fault indication per NAMUR NE43; HART communication option.
- Second output for pulse, Modbus RTU (RS485), or BACnet MS/TP (RS485).
- Isolated pulse output: 5 to 24VDC, 10mA max, 0 to 100Hz for flow.
- The pulse output can be used as an isolated sold state output for alarms.
Port:
Mini USB communication port is standard.
Software:
The free PC-based software tool - FT1 View™ - provides complete configuration, remote process monitoring, and data logging functions.
Optional serial communication:
Modbus RTU (RS485), BACnet MS/TP (RS485) or HART (when no pulse output has been ordered).
4-20mA and Pulse Verification:
Simulation mode used to align 4-20mA output and pulse output (if ordered) with the input to customer’s PLC/DCS.
- WISE CONTROL
- REDLION
- TDK LAMBDA
- MATSUSHIMA
- GASTRON
- AT2E
- KELLER ITS
- TECLOCK
- IBA
- SCHENCK PROCESS
- AUTROL
- BECKHOFF
- BIRCHER
- BAUMUELLER
- BROOK INSTRUMENT
- BRONKHORST
- CEIA
- CEMB
- CS INSTRUMENTS
- COMET SYSTEM
- DWYER
- ELCO HOLDING
- EUROSWITCH
- ENDRESS + HAUSER
- FIREYE
- FOX THERMAL
- FINETEK
- GEMU
- IPF ELECTRONIC
- INTORQ
- KEOFITT
- KIEPE
- KOMETER
- KROHNE
- LABOM
- MARK-10
- METRIX VIBRATION
- MKS ANLASSER
- MAGNETEK
- PCI INSTRUMENT
- OHKURA
- PORA
- PAVONE SISTEMI
- RIELS
- ROTORK
- SORINC
- SHINHO SYSTEM
- STAUBLI
- SPOHN+BURKHARDT
- TEMAVASCONI
- TEK-TROL
- TEMPSENS
- VEGA
- YOUNGTECH
- ZAMA SENSOR
- VALPES
- LAPAR
- ASHCROFT
- MAXCESS
- NORGREN
- OKAZAKI
- MINIMAX
- UTILCELL
- KRACHT
- GÜNTHER
- ROSEMOUNT
- AROMANIKKI
- MEDENUS
- SAUTER
- HELUKABEL
-
Trực tuyến:4
-
Hôm nay:1843
-
Tuần này:86196
-
Tuần trước:16398
-
Tháng trước:96404
-
Tất cả:3205601