Thiết bị đo lưu lượng FT2A Fox Thermal

Xuất xứ:
USA
Tình trạng:
Mới 100%
Mô tả:
Fox Thermal Instrument
Thành phần:
Flowmeter
Mã sản phẩm:
FT2A

Nhà phân phối Flowmeter Fox Thermal Instruments chính hãng tại Việt Nam

Thiết bị đo lưu lượng FT2A Fox Thermal

Fox Thermal Vietnam

FT2A Fox Thermal | Đồng hồ đo lưu lượng khí Fox Thermal

Fox Thermal Model FT2A Thermal Gas Mass Flow Meter

The Model FT2A has a large selection of communication protocol options available intrinsically (without any other equipment). Options include: BACnet MS/TP, RS485 Modbus RTU, Profibus-DP, DeviceNet, or Ethernet Modbus TCP. 

Key Features:

  • Insertion, Inline & Remote Styles
  • USB Port, free FT2A View™ Software
  • 2 x 4-20mA outputs
  • FM/FMc approvals
  • Scroll down for more features/benefits!

Industrial Applications:

  • Aluminum & Steel Production
  • Chemical Plants
  • Glass & Ceramics Production
  • Pulp & Paper Production

Thiết bị đo lưu lượng

Technical Specifications
Fox Thermal Model FT2A Thermal Mass Flow Meter & Temperature Transmitter
Performance Specs
Type Insertion Inline
Flow Accuracy: ± 1% of reading ± 0.2% of full scale.
15 diameters of straight, unobstructed pipe upstream and 10 downstream.
± 1% of reading ± 0.2% of full scale.
8 diameters of straight, unobstructed pipe upstream and 4 downstream.
Flow Repeatability: ± 0.2% of full scale
Flow Response Time: 0.9 seconds (one time constant)
Temperature Accuracy: ± 1.8°F (± 1.0°C) -40 to 250°F (-40 to 121°C); ± 3.6°F (± 2.0°C), 250 to 650°F (121 to 343°C); 60 SFPM minimum.
Calibration: Factory Calibration to NIST-traceable standards
Operating Specs
Type Insertion Inline
Flow Units (field selectable): SCFM, SCFH, NMPS, NM3/M, NM3/H, NM3/D, NLPS, NLPM, NLPH, MCFD, MSCFD, SCFD, MMSCFD, MMSCFM, SMPS, SM3/H, LB/S, LB/M, LB/H, LB/D, KG/S, KG/M, KG/H, SLPM, SFPM, MT/H, SM3/M
Flow Rates: 15 to 60,000 SFPM (0.07 to 280 NMPS) - Air at 70°F (20°C) & 1 ATM
Turndown: up to 1000:1; 100:1 typical
Flow Ranges:
Pipe Size SCFM NM³/Hr
1.5" (40mm) 0 - 840 0 - 1,325
2" (50mm) 0 - 1,400 0 - 2,210
2.5" (63mm) 0 - 2,000 0 - 3,150
3" (80mm) 0 - 3,100 0 - 4,890
4" (100mm) 0 - 5,300 0 - 8,360
6" (150mm) 0 - 12,000 0 - 18,930
8" (200mm) 0 - 20,840 0 - 32,870
10" (250mm) 0 - 32,800 0 - 51,740
12" (300mm) 0 - 46,600 0 - 73,500
Pipe Size SCFM NM³/Hr
0.25" 0 - 7.5 0 - 11.8
0.5" 0 - 125 0 - 200
0.75" 0 - 220 0 - 350
1" 0 - 360 0 - 570
1.25" 0 - 625 0 - 990
1.5" 0 - 840 0 - 1,325
2" 0 - 1,400 0 - 2,210
2.5" 0 - 2,000 0 - 3,150
3" 0 - 3,100 0 - 4,890
4" 0 - 5,300 0 - 8,360
6" 0 - 12,000 0 - 18,930
Note: Standard conditions of air at 70°F and one atmosphere.
Consult factory for other gases, pipe sizes, and flow ranges other than those listed.
Gas Pressure (max): 500 psig (34.5 barg) 316 SS inline w/NPT ends: 300 psig (20 barg)
316 SS inline w/150lb flanges: 230 psig (16 barg)
CS inline w/NPT ends: 300 psig (20 barg)
CS inline w/150lb flanges: 285 psig (20 barg)
Check with factory for higher pressure options.
Note: Pressure ratings stated for temperature of 100°F (38°C).
Relative Humidity: 90% RH maximum; non-condensing
Temperature by Sensor Type: ST Sensor: -40 to 250°F (-40 to 121°C)
HT Sensor: -40 to 650°F (-40 to 343°C)
Temperature by Enclosure: DC Power: -40 to 158°F (-40 to 70°C)
AC Power: -4 to 158°F (-20 to 70°C)
Inputs Power (Power Consumption):
  • Input Power (without the Anybus serial communication option): 24VDC, (±10%), 0.4 Amps (standard DC Power) 100 to 240VAC ~(+10%-15%), 50-60Hz, 0.2 Amps (with AC power option).
  • Input Power (with Anybus serial communication option): 24VDC, (±10%), 0.7 Amps (standard DC Power) 100 to 240VAC ~(+10%-15%), 50-60Hz, 0.2 Amps (with AC power option).

Note: Fluctuations of AC and DC power supply are not to exceed ±10% of rating.

Outputs:
  • Two isolated 4-20mA outputs (one for flow rate & a second is programmable for flow rate or temperature); fault indication per NAMUR NE43.
  • Isolated pulse output 0 to 100Hz, 5 to 24 volts p/p for flow (the pulse output can be used as an isolated solid state output for alarms); 10mA max.
  • USB connector for connecting to a laptop or computer is standard; free PC-based software tool - FT2A View™ - provides complete configuration, remote process monitoring and data logging functions.
  • Optional isolated communication outputs: RS485-Modbus, BACnet MS/TP, Profibus-DP, DeviceNet or Ethernet Modbus TCP.
Port: Mini USB communication port is standard.
Software: The free PC-based software tool - FT2A View™ - provides complete configuration, remote process monitoring, and data logging functions.
Optional serial communication: Modbus RTU (RS485), BACnet MS/TP (RS485), Profibus-DP, DeviceNet or Ethernet Modbus TCP.
4-20mA Loop Verification: Simulation mode used to align 4-20mA output with the input to customer’s PLC/DCS.
Bình luận của bạn
*
*
*
*
 Captcha
Chia sẻ:
Danh mục sản phẩm
Thống kê truy cập
  • Trực tuyến:
    3
  • Hôm nay:
    1839
  • Tuần này:
    86192
  • Tuần trước:
    16398
  • Tháng trước:
    96400
  • Tất cả:
    3205597
Video Clip

CÔNG TY TNHH THƯƠNG MẠI VÀ DỊCH VỤ TĂNG MINH PHÁT

Địa chỉ: Số 1, Đường số 27, phường Hiệp Bình Chánh, Quận Thủ Đức, Tp.HCM.

Hoàng Xuân Tiến (Mr)

Hotline: 03888 30881

Email: sale06@tmpvietnam.com

© 2018 Tang Minh Phat , all rights reserved